World Leading Manufacturer of Fountains and Display Aerators

Electrical

Water Controls, Wind Controls, Variable Frequency Drive, Photocell, Digital Timer, a Healthy Variety of Cable in Different Gauges and Control Panels for All Aqua Control® Applications, Also Sold Separately.

Control Panels

EVOLUTION Series
Control Panel 0.5HP


FUSION Series

Control Panel 0.5HP


• NEMA 3R fiberglass outdoor enclosure
• Compact size
• Padlock compatible
• Individual GFCI protection for motor & lights
• Built standard with 1 light circuit
• 24 hour pump & light timer photo cell
• Ground connectors


Click for Evolution Series Patterns
Click for Fusion Series Patterns

FUSION Series
Control Panel 1.0HP – 2.0HP


• Composite outdoor enclosure
• Compact size
• Padlock compatible
• Through-the-door safety disconnect switch with lockout capability
• Individual GFCI protection for motor & lights
• Built standard with 1 light circuit (multiple light circuits available)
• 24 hour pump timer and photocell
• Ground connectors
• Wire ways for neat & safe wiring
• Most components are DIN rail mounted for ease of service
• Easy to read schematics


Click for Fusion Series Patterns

Standard Control Panel

SELECT Series

Control Panel 1.0HP – 5.0HP

SELECT Series 2

Control Panel 1.0HP – 7.5HP

COMBO Series

Control Panel 3.0HP and 5.0HP

TITAN Series

Control Panel 7.5HP – 40.0HP


• Minimum NEMA 4X fiberglass outdoor enclosure
• Compact size
• Stainless steel hardware
• Padlock compatible
• Through-the-door safety disconnect switch with lockout capability
• Individual GFCI protection for motor & lights
• Built standard with 1 light circuit (multiple light circuits available)
• 24-hour pump & light timers
• Ground connectors
• Wire ways for neat & safe wiring
• Most components are DIN rail mounted for ease of service
• Easy to read schematics
• Single phase panels include: capacitors, start circuit & re-settable overloads
• Standard single-phase panels are UL listed
• CE rated 50Hz control panels are available


Click for Select Series
Click for Select Series 2
Click for Combo Series
Click for Titan Series

Custom Large Control Panel Build


• Operates multiple units in one panel
• For panels with upgraded control panel options
• NEMA 4X powder-coated steel
• Locking handle
• Stainless steel hardware
• Through-the-door safety disconnect switch with lockout capability
• Individual GFCI protection for motor & lights
• Built standard with 1 light circuit (multiple light circuits available)
• Wire ways for neat & safe wiring
• 24 hour pump & light timers
• Ground connectors
• Ease of service DIN rail mounted for most components
• Easy to read schematics
• Single phase panels include: capacitors, start circuit & re-settable overloads
• Standard single phase panels are UL listed
• CE rated 50Hz control panels are available


Water Level Controller and Sensor

Turns off the water feature pump to prevent motor damage caused by no-flow operation. Turns on an external water fill valve.

Single-Point: When water Levolor® probe points are no longer submerged, it prevents the pump from operating.

Two-Point: Includes two water Levolor® probes. One probe, set at a higher point, turns on a valve once the water level falls below the probe. A second probe, set at a lower point, prevents the pump from operating once it is no longer submerged.

Wind Control

Used in conjunction with our fountain manager (shown), the externally mounted anemometer sends a signal back to the Control Panel indicating wind speed and reduces the spray height or shuts down the unit depending on settings and options.

Wind Control Options:

Single-Point Wind Control: Prevents operation of unit when the wind speed exceeds an adjustable preset limit. (off only)

Two-Point Wind Control: In addition to preventing operation of the unit (see single-point), TWO-POINT wind control also allows the spray pattern height to be reduced to preset point based on wind speed. (lower height and off)

Inverse Wind Control: As wind speed increases, the spray pattern decreases proportionately between two adjustable preset wind speeds. Unit operation is prevented when a higher preset level is exceeded.

Variable Frequency Drive (VFD)

Used in conjunction with the fountain manager, to vary the speed of the motor and pump, the VFD is capable of reducing the height of patterns, preventing excessive wind blown spray. The VFD can also be used to create three phase power when only single phase power is available.

Photo Cell

A photo cell allows the lights to turn on at dusk and off at dawn unless a light timer is set to shut the lights off sooner. A photo cell must be installed where natural light is present, not in the shade or under man-made lighting.

Digital Timer

7-day programmable timer with up to 8 different on/off brackets. Easy to program, compact, backlit LCD, backup battery.

Motor Cables

60 Hz Motor Cables

Select Series and Select Series 2
Angel, Niagara, and Niagara II Waterfalls
Bottom Circulators

Cables supplied by Aqua Control are America Wire Gauge (AWG) cables, not square millimeter cables.
N/A = Not Available in AWG Cable

60 Hz Motor Cables

Fusion Series and Havasu Waterfalls
Titan Series and Titan Stationary Series
Yosemite Waterfall

50 Hz Motor Cables

Select Series and Select Series 2
Angel, Niagara, and Niagara II Waterfalls
Stationary Series and Bottom Circulators

Cables supplied by Aqua Control are America Wire Gauge (AWG) cables, not square millimeter cables.
N/A = Not Available in AWG Cable

50 Hz Motor Cables

Fusion Series and Havasu Waterfalls
Titan Series and Titan Stationary Series
Yosemite Waterfall